Indoor AC metal-enclosed ring main unit switchgear is suitable for indoor three-phase 50/60Hz, rated voltage 7.2~12kV power systems. It is used to receive and distribute three-phase AC power and to automatically control the switching of operating circuits, protect against faults (including overload, short circuit, overvoltage, etc.), monitor, and record events. This product is characterized by its small size, light weight, simple operation, safe use, and easy maintenance; it is widely used in urban power grid construction and renovation projects, industrial and mining enterprises, high-rise buildings, and public facilities, as a ring main power supply unit and terminal equipment, and can also be installed in prefabricated substations.
The design and manufacture of HXGN-12 ring main units fully comply with GB/T 3096 "3.6kV-40.5kV AC metal-enclosed switchgear and control equipment", GB/T 3804 "3.6kV-40.5kV high-voltage AC load switches", GB/T 1985 "High-voltage AC isolating switches and earthing switches", GB16926 "High-voltage AC load switch-fuse combination electrical appliance", GB/T1984 "High-voltage AC circuit breaker", DL/T 404 "3.6kV-40.5kV AC metal-enclosed switchgear and control equipment".
Technical Advantages
1. The cabinet shell is a metal-enclosed high-voltage switchgear assembled from reinforced profiles independently developed by the company;
2. This equipment has strong completeness, small size, no risk of combustion or explosion, and reliable "five-proof" function;
3. This product can have load switch units, load switch and fuse combination electrical appliance units, and circuit breaker units, and various design schemes can be selected according to user needs;
4. It can be designed for application in plateau areas with an altitude of 4500m or less.
Technical Parameters
|
Serial Number |
Item |
Unit |
Load Switch Unit |
Combination Electrical Appliance Unit |
Circuit Breaker Unit |
||
|
1 |
Rated Voltage |
kV |
12 |
12 |
12 |
||
|
2 |
Rated Frequency |
Hz |
50 |
50 |
50 |
||
|
3 |
Rated Current |
A |
630 |
200 (depends on fuse current) |
1250 |
||
|
4 |
Rated Insulation Level |
1min power frequency withstand voltage |
Phase-to-phase, phase-to-ground |
kV |
42 |
42 |
42 |
|
Break |
48 |
48 |
48 |
||||
|
Control and auxiliary circuit |
2 |
2 |
2 |
||||
|
Lightning impulse withstand voltage |
Phase-to-phase, phase-to-ground |
75 |
75 |
75 |
|||
|
Break |
85 |
85 |
85 |
||||
|
5 |
Rated short-time withstand current |
kA/s |
20/4 |
-- |
31.5/4 |
||
|
6 |
Rated peak withstand current |
kA |
63 |
-- |
80 |
||
|
7 |
Rated short-circuit closing current |
kA |
50 |
Limited by high-voltage fuse |
80 |
||
|
8 |
Rated short-circuit breaking current |
kA |
-- |
Limited by high-voltage fuse |
31.5 |
||
|
9 |
Rated transfer current |
A |
-- |
1700/1400 |
-- |
||
|
10 |
Mechanical Life |
Circuit Breaker |
Times |
10000 |
10000 |
10000 |
|
|
Load Switch |
2000 |
2000 |
-- |
||||
|
Isolating Switch |
2000 |
2000 |
-- |
||||
|
Earthing Switch |
2000 |
2000 |
1000 |
||||
|
12 |
IP Protection Level |
Enclosure |
|
IP41 |
IP41 |
IP4X |
|